Training Videos: BD FACSMelody? Cell Sorter

At BD, we provide innovative instruments, reagents and software to support scientists throughout the full continuum of flow cytometry experiments.

On this page you will find helpful training videos to get started on and maintain your BD FACSMelody™ Cell Sorter.

Intro Image

BD FACSMelody™ Cell Sorter: Getting Started

BD FACSMelody™ Cell Sorter: Getting Started (03:53)

Learn how to turn on the system, check the fluid tanks and load a sample.

View Now


BD FACSMelody™ Cell Sorter: System Startup

BD FACSMelody™ Cell Sorter: System Startup (07:33)

Learn how to run a daily fluidics startup, insert the sort nozzle and run a cytometer setup with drop delay.

View Now


BD FACSMelody™ Cell Sorter: Design Experiment

BD FACSMelody™ Cell Sorter: Design Experiment (03:49)

Learn how to use the Design Experiment tab as the first step to define your sort experiment parameters.

View Now


BD FACSMelody™ Cell Sorter: View Data

BD FACSMelody™ Cell Sorter: View Data (06:25)

Learn how to use the View Data tab to determine the layout of experiment data including optimizing threshold and scatter settings of a sort sample and collecting a pre-sort data file.

View Now


BD FACSMelody™ Cell Sorter: Set Up and Sort

BD FACSMelody™ Cell Sorter: Set Up and Sort (06:49)

Learn how to set up and perform a sort. Then, view and export the report for each sort operation.

View Now


BD FACSMelody™ Cell Sorter: Daily Shutdown

BD FACSMelody™ Cell Sorter: Daily Shutdown (03:51)

Learn how to perform a daily shutdown to clean the sample path and how to prepare the flow cell for shutdown.

View Now


BD FACSMelody™ Cell Sorter: Loading the Collection Devices

BD FACSMelody™ Cell Sorter: Loading the Collection Devices (03:28)

Learn how to set up and load a tube holder, as well as a plate on the automated stage.

View Now


BD FACSMelody™ Cell Sorter: Cleaning the Flow Cell

BD FACSMelody™ Cell Sorter: Cleaning the Flow Cell (03:51)

Learn how to perform a flow cell clean, as well as an optional flow cell scrubbing procedure.

View Now


BD FACSMelody Cell Sorter: Cleaning the Nozzles

BD FACSMelody™ Cell Sorter: Cleaning the Nozzles (04:51)

Learn how to clean the sort nozzle and the closed-loop nozzle.

View Now


BD FACSMelody™ Cell Sorter: Cleaning the Deflection Plates

BD FACSMelody™ Cell Sorter: Cleaning the Deflection Plates (03:04)

Learn how to remove and clean the deflection plates.

View Now


BD FACSMelody™ Cell Sorter: Cleaning Laser and Camera Windows

BD FACSMelody™ Cell Sorter: Cleaning Laser and Camera Windows (05:35)

Learn when and how to clean the strobe lens window, upper camera window, the Accudrop laser window and lower camera window.

View Now


BD FACSMelody™ Cell Sorter: Performing an Index Sort

BD FACSMelody™ Cell Sorter: Performing an Index Sort (05:59)

Learn how to set up and complete an index sort.

View Now


BD FACSMelody™ Cell Sorter: Update Compensation

BD FACSMelody™ Cell Sorter: Update Compensation (06:13)

Learn how to update compensation in BD FACSChorus? Software using your own controls for your experiment.

View Now


BD FACSMelody™ Cell Sorter: Changing the Fluid Filter

BD FACSMelody™ Cell Sorter: Changing the Fluid Filter (05:04)

Learn how to change a fluid filter and prepare a new filter to prevent bubble formation.

View Now


BD FACSMelody™ Cell Sorter: Preparing for an Aseptic Sort - 1 Tank Method

BD FACSMelody™ Cell Sorter: Preparing for an Aseptic Sort - 1 Tank Method (06:26)

Learn how to clean your entire system of any potential contaminants in preparation for an aseptic sort using the provided sheath tank.

View Now


BD FACSMelody™ Cell Sorter: Preparing for an Aseptic Sort - 2 Tank Method

BD FACSMelody™ Cell Sorter: Preparing for an Aseptic Sort - 2 Tank Method (07:02)

Learn how to clean your entire system of any potential contaminants in preparation for an aseptic sort using the two tank method.

View Now


BD FACSMelody™ Cell Sorter: Aligning the Automated Stage

BD FACSMelody™ Cell Sorter: Aligning the Automated Stage (07:11)

Learn how to properly check, adjust, confirm and test alignment to ensure each sorted drop falls into the exact center of each well or slide.

View Now


BD FACSMelody™ Cell Sorter: Replacing the Sample Line

BD FACSMelody™ Cell Sorter: Replacing the Sample Line (10:14)

Learn when and how to replace the sample line to prevent clogging.

View Now




Class 1 Laser Product.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.